JIE USA

JANOME Industrial Equipment USA
PERIODICAL PREVENTIVE MAINTENANCE PROGRAM

Prevent problems
before they happen…

Regular maintenance and inspection, including load accuracy calibration, is the best way to ensure the stable operation of your equipment.

Please contact us to help you develop the best maintenance plan for your facility.

Recommended Maintenance Program

*Scroll Horizontally

  For JP4 For JP-S/JP-S2 For JP5
● Cleaning of the unit and lubrication of grease Annually Annually Annually
● Load cell load calibration Annually Annually Annually
● Checking the timing belt Annually Annually Annually
● Checking the brakes Annually Annually Annually
● Checking the cooling fan Annually Annually Annually
● Replacement of the filter (Optional)
(JPU2005-8005 Controller)
N/A N/A Annually
● Replacement of bellows (Cleanroom model) Annually N/A Annually
● Backup battery replacement N/A Every 3 yrs. N/A
● Encoder batteries (Absolute Encoder Models) Every 3 yrs. N/A Every 3 yrs.
● Checking the electromagnetic contactor at power ON Every 5 yrs. N/A N/A
● Fuse replacement (Standard Controller) N/A N/A Every 5 yrs.
● Overhaul (Depending on Usage) Every 2 yrs. Annually Every 2 yrs.

These are general recommendations based upon average use. Actual maintenance needs may vary due to frequency of use and other factors.

If you've been using our machines for 10 years or more, its probably time for a tune-up, so please be sure to contact us.

Technical Support Email (for US Customers)

pcohen@janomeie.com

Contact form